Clinker Cooling Fan Cone and Damper Erosion Detection
SKYLER
1. Slow increase in the acceleration velocity vibration since Jan 2025.

2. Reached 0.6 IPS 27th February, severe degradation report sent with airflow issue suspicion.
Asset was monitored by both Skyler and a different PdM provider. Skyler correctly identified the fault, while the other didn’t. Fan inspected 28th February during short stop. Eroded fan cone found, damper not closing and starting to delaminate.

3. Holes patched with `5-minute stee
Trends and impacting decreases back to January lev
The Result?
$41,568 in savings for downtime, fan wheel
and bearings replacement.